Search:
  
Main > TPU > Administration > English > Products > X-ray tomograph of large-scale objects
Laboratory of Technical Tomography and Introscopy
  
    X-ray tomograph of large-scale objects     
Cooperative product with High-Current Betatrons Lab №42

Main Technical Specification:
Spase resolution of tomogram, mkm 150
Object diameter, mm 1500
Object weight, kg 1000
Scope of working region, mm 2000х2740х2320
X-ray source - betatron (under development) MIB-7 (TPU)
Electron energy, MeVдо 7
Focal spot, mm 1х0.3
X-ray source - X-ray tube MXR-451HP/11(COMET)
Anode voltage, kVup 450
Power, W700 or 1500
Focal spot, mm0.4 or 1.0
Detector - flat panel XRD-1642 (PerkinElmer)
Detector size 2048х2048
Detector resolution, mkm 200
Detector - array (not mounted) X-Scan 0.4iHE2-410 M (Detection Technology)
Number of detectors 1024
Detector resolution, mkm 400